<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>The Fire People</title>
	<atom:link href="https://thefirepeople.co.uk/feed/" rel="self" type="application/rss+xml" />
	<link>https://thefirepeople.co.uk</link>
	<description>Fire Safety Specialists</description>
	<lastBuildDate>Mon, 09 Nov 2026 18:45:27 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://thefirepeople.co.uk/wp-content/uploads/2024/08/cropped-5303B18A-DF36-4F4E-9B43-268AC305E591-32x32.png</url>
	<title>The Fire People</title>
	<link>https://thefirepeople.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fire Risk Assessments Before the New Academic Year</title>
		<link>https://thefirepeople.co.uk/fire-risk-assessments-before-the-new-academic-year/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fire-risk-assessments-before-the-new-academic-year</link>
					<comments>https://thefirepeople.co.uk/fire-risk-assessments-before-the-new-academic-year/#respond</comments>
		
		<dc:creator><![CDATA[The Fire People]]></dc:creator>
		<pubDate>Thu, 16 Jul 2026 09:17:25 +0000</pubDate>
				<category><![CDATA[Fire Risk Assessment]]></category>
		<category><![CDATA[fire safety]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1188</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_0 et_pb_section et_section_regular et_flex_section">
<div class="et_pb_row_0 et_pb_row et_flex_row">
<div class="et_pb_column_0 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">As the summer holidays begin, many organisations use the quieter months to prepare for September. Schools and colleges get classrooms ready for students, universities prepare accommodation, landlords welcome new tenants, and retailers begin increasing stock ahead of the busier autumn period.</span></p>
<p><span style="font-weight: 400;">It's also one of the best times to review fire safety.</span></p>
<p><span style="font-weight: 400;">A commercial </span><a href="https://thefirepeople.co.uk/fire-risk-assessments/"><b>fire risk assessment</b></a><span style="font-weight: 400;"> helps identify potential fire hazards before buildings become fully occupied again. Completing any recommended improvements during the summer can reduce disruption and help ensure your premises are safe, compliant and ready for the months ahead.</span></p>
<p><span style="font-weight: 400;">Whether you manage a school, office, retail premises, HMO or another commercial property, planning ahead can make all the difference when occupancy increases.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_1 et_pb_row et_flex_row">
<div class="et_pb_column_1 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_0 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Why Arrange a Commercial Fire Risk Assessment Before September?</h2></div></div>
</div>
</div>

<div class="et_pb_row_2 et_pb_row et_flex_row">
<div class="et_pb_column_2 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_1 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Summer provides a valuable opportunity to review your fire safety arrangements while many buildings are quieter than usual. Carrying out a commercial fire risk assessment before September allows time to identify potential hazards, complete any remedial work and ensure your premises are prepared before staff, students, customers or tenants return.</span></p>
<p><span style="font-weight: 400;">For schools, colleges and universities, September brings a significant increase in occupancy. New students arrive, classrooms become busy again and accommodation reaches full capacity. The same applies to HMOs and student housing, where a change of tenants often means new fire safety responsibilities need to be reviewed.</span></p>
<p><span style="font-weight: 400;">Retailers also experience changes during this period. Many businesses begin increasing stock levels ahead of autumn and Christmas, often altering shop layouts or using additional storage space. Warehouses may also become busier as deliveries increase.</span></p>
<p><span style="font-weight: 400;">Any change to how a building is used has the potential to introduce new fire risks. Escape routes may become obstructed, additional electrical equipment may be installed, or storage arrangements may change. Reviewing these risks before the building becomes busy again helps avoid unnecessary disruption later.</span></p>
<p><span style="font-weight: 400;">Rather than waiting until September, carrying out your assessment during July or August gives you the opportunity to address any issues before they affect day-to-day operations.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_3 et_pb_row et_flex_row">
<div class="et_pb_column_3 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_1 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Which Buildings Should Have a Fire Risk Assessment for Commercial Premises?</h2></div></div>
</div>
</div>

<div class="et_pb_row_4 et_pb_row et_flex_row">
<div class="et_pb_column_4 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_2 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">The Regulatory Reform (Fire Safety) Order 2005 places a legal responsibility on the Responsible Person to ensure suitable fire safety measures are in place within most non-domestic premises.</span></p>
<p><span style="font-weight: 400;">A fire risk assessment for commercial premises is therefore an essential part of managing fire safety and protecting those who use the building.</span></p>
<p><span style="font-weight: 400;">Properties that may benefit from a review before September include:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Schools and academies</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Colleges and universities</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Student accommodation</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">HMOs</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Office buildings</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Retail premises</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Warehouses</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Healthcare facilities</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Hotels and hospitality venues</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Industrial units</span></li>
</ul>
<p><span style="font-weight: 400;">Even if your premises already has a fire risk assessment, it should not simply be filed away and forgotten.</span></p>
<p><span style="font-weight: 400;">The assessment should reflect how the building is currently used. If layouts have changed, occupancy has increased, or new equipment has been introduced, your fire risks may also have changed.</span></p>
<p><span style="font-weight: 400;">For many organisations, the summer break provides the ideal opportunity to review existing arrangements before normal operations resume.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_5 et_pb_row et_flex_row">
<div class="et_pb_column_5 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_2 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">What Does a Commercial Fire Risk Assessment Cover?</h2></div></div>
</div>
</div>

<div class="et_pb_row_6 et_pb_row et_flex_row">
<div class="et_pb_column_6 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_3 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">A fire risk assessment is much more than a checklist. It provides a structured review of your building, identifying potential hazards and recommending practical measures to reduce risk.</span></p>
<p><span style="font-weight: 400;">A competent assessor will consider several key areas, including:</span></p>
<h3><b>Fire hazards</b></h3>
<p><span style="font-weight: 400;">Potential sources of ignition, fuel and oxygen are identified to understand where fires could start and how they could spread.</span></p>
<h3><b>People at risk</b></h3>
<p><span style="font-weight: 400;">Particular attention is given to employees, visitors, contractors, customers, residents and anyone who may require additional assistance during an evacuation.</span></p>
<h3><b>Means of escape</b></h3>
<p><span style="font-weight: 400;">Escape routes should remain clear, adequately signed and capable of being used safely in an emergency.</span></p>
<h3><b>Fire detection and warning systems</b></h3>
<p><span style="font-weight: 400;">Fire alarm systems should be suitable for the building, correctly maintained and capable of providing sufficient warning if a fire occurs.</span></p>
<h3><b>Emergency lighting</b></h3>
<p><span style="font-weight: 400;">Emergency lighting should operate correctly should the main power supply fail, allowing occupants to leave the building safely.</span></p>
<h3><b>Fire-fighting equipment</b></h3>
<p><a href="https://thefirepeople.co.uk/fire-extinguishers/"><b>Fire extinguishers</b></a><span style="font-weight: 400;"> should be appropriate for the risks within the building and maintained in accordance with current standards.</span></p>
<h3><b>Fire doors and compartmentation</b></h3>
<p><span style="font-weight: 400;">Fire doors play an important role in slowing the spread of fire and smoke. Damage or poor maintenance can reduce their effectiveness.</span></p>
<p><span style="font-weight: 400;">Following the assessment, recommendations are provided to help the Responsible Person improve fire safety where required. This report forms the foundation of your ongoing fire safety management and helps demonstrate compliance with current legislation.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_7 et_pb_row et_flex_row">
<div class="et_pb_column_7 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_3 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">When Should a Fire Risk Assessment Be Reviewed?</h2></div></div>
</div>
</div>

<div class="et_pb_row_8 et_pb_row et_flex_row">
<div class="et_pb_column_8 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_4 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Many business owners assume that once a fire risk assessment has been completed, no further action is required. In reality, fire safety should be reviewed regularly.</span></p>
<p><span style="font-weight: 400;">In most cases, fire risk assessments should be reviewed every 12 months. However, they should also be reviewed whenever significant changes take place within the building.</span></p>
<p><span style="font-weight: 400;">Examples include:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Changes to the building layout</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Alterations or refurbishment work</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Increased occupancy</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">New equipment or machinery</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Changes to working practices</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Additional storage</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">A change in the building's use</span></li>
</ul>
<p><span style="font-weight: 400;">The period before September often includes several of these changes, making it an appropriate time to review your existing assessment.</span></p>
<p><span style="font-weight: 400;">Keeping your fire risk assessment up to date helps ensure it continues to reflect the current risks within your premises rather than those that existed several years ago.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_9 et_pb_row et_flex_row">
<div class="et_pb_column_9 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_4 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Why Experience Matters</h2></div></div>
</div>
</div>

<div class="et_pb_row_10 et_pb_row et_flex_row">
<div class="et_pb_column_10 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_5 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Fire risk assessments should always be completed by someone who is competent and experienced.</span></p>
<p><span style="font-weight: 400;">An experienced assessor understands current legislation, British Standards and recognised industry guidance. More importantly, they can provide practical recommendations that are appropriate for your building rather than applying a generic approach.</span></p>
<p><a href="https://thefirepeople.co.uk/"><b>The Fire People</b></a><span style="font-weight: 400;"> has decades of experience carrying out fire risk assessments for commercial premises across South Wales. Every assessment is completed by a competent and experienced assessor, providing practical recommendations to help Responsible Persons identify fire hazards, reduce risks and comply with current fire safety legislation.</span></p>
<p><span style="font-weight: 400;">Whether your premises is preparing for the new academic year, changes in occupancy or alterations to its layout, an up-to-date fire risk assessment helps ensure your fire safety measures remain appropriate for both the building and the people who use it.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_11 et_pb_row et_flex_row">
<div class="et_pb_column_11 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_5 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Book Your Fire Risk Assessment Before September</h2></div></div>
</div>
</div>

<div class="et_pb_row_12 et_pb_row et_flex_row">
<div class="et_pb_column_12 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_6 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">If your premises will become busier over the coming months, now is an ideal time to review your fire safety arrangements.</span></p>
<p><span style="font-weight: 400;">Arranging a commercial fire risk assessment during the summer allows any recommendations to be completed before occupancy increases, helping minimise disruption while ensuring your building remains safe and compliant.</span></p>
<p><span style="font-weight: 400;">At The Fire People, we provide professional fire risk assessments for commercial premises across South Wales. Our experienced assessors work with schools, colleges, landlords, retailers, offices and businesses of all sizes, delivering practical advice and comprehensive reports tailored to your premises.</span></p>
<p><span style="font-weight: 400;">If you would like to arrange a fire risk assessment or discuss your fire safety requirements, </span><a href="https://thefirepeople.co.uk/contact-us/"><b>contact</b></a><span style="font-weight: 400;"> The Fire People today.</span></p>
<p>&nbsp;</p>
</div></div>
</div>
</div>
</div>]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/fire-risk-assessments-before-the-new-academic-year/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>How Regular Dry Riser Maintenance Helps Prevent Emergencies</title>
		<link>https://thefirepeople.co.uk/how-regular-dry-riser-maintenance-helps-prevent-emergencies/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=how-regular-dry-riser-maintenance-helps-prevent-emergencies</link>
					<comments>https://thefirepeople.co.uk/how-regular-dry-riser-maintenance-helps-prevent-emergencies/#respond</comments>
		
		<dc:creator><![CDATA[The Fire People]]></dc:creator>
		<pubDate>Fri, 19 Jun 2026 12:16:35 +0000</pubDate>
				<category><![CDATA[Dry Riser]]></category>
		<category><![CDATA[Fire Safety]]></category>
		<category><![CDATA[Fire Safety At Work]]></category>
		<category><![CDATA[dry riser]]></category>
		<category><![CDATA[dry riser maintenance]]></category>
		<category><![CDATA[fire safety]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1175</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_2 et_pb_section et_section_regular et_flex_section">
<div class="et_pb_row_32 et_pb_row et_flex_row">
<div class="et_pb_column_32 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_17 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><a href="https://thefirepeople.co.uk/fire-alarms/"><b></b></a>When a fire occurs in a multi-storey building, emergency services need quick access to a reliable water supply. A dry riser system helps firefighters deliver water to upper floors without running hoses throughout the building, saving valuable time when every second counts.</p>
<p><span style="font-weight: 400;">However, a dry riser is only effective if it is properly maintained. Like any fire safety system, components can deteriorate over time through wear, weather exposure and general use. Regular </span><a href="https://thefirepeople.co.uk/dry-riser-testing/"><b>dry riser maintenance</b></a><span style="font-weight: 400;"> helps identify issues before they become serious problems and ensures the system is ready when needed.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_33 et_pb_row et_flex_row">
<div class="et_pb_column_33 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_15 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Why Dry Risers Are Often Overlooked</h2></div></div>
</div>
</div>

<div class="et_pb_row_34 et_pb_row et_flex_row">
<div class="et_pb_column_34 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_18 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Unlike fire alarms, emergency lighting or </span><a href="https://thefirepeople.co.uk/fire-extinguishers/"><b>fire extinguishers</b></a><span style="font-weight: 400;">, dry risers are not something most building occupants see or interact with on a daily basis. Once installed, they are often hidden within stairwells, service areas and riser cupboards, making them easy to forget about until maintenance becomes due.</span></p>
<p><span style="font-weight: 400;">Because dry risers are only used during a fire, some property owners assume that if there are no visible issues, the system must be working correctly. Unfortunately, faults can develop over time without obvious signs. Corrosion, damaged valves, worn seals and leaks can all affect the performance of a dry riser system, even if the system appears to be in good condition from the outside.</span></p>
<p><span style="font-weight: 400;">This is why regular dry riser maintenance is so important. Routine servicing, dry riser inspection and dry riser testing help identify issues before they affect the system's performance. Rather than waiting for a fault to be discovered during an emergency, building owners can address problems early and ensure the system remains ready for use when firefighters need it most.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_35 et_pb_row et_flex_row">
<div class="et_pb_column_35 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_16 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">What Can Happen When a Dry Riser Is Not Maintained?</h2></div></div>
</div>
</div>

<div class="et_pb_row_36 et_pb_row et_flex_row">
<div class="et_pb_column_36 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_19 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Dry risers are often out of sight and may go months or even years without being used. Because of this, faults can develop unnoticed.</span></p>
<p><span style="font-weight: 400;">Some of the most common issues found during maintenance visits include:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Corroded pipework or valves</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Damaged inlet or outlet connections</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Missing caps and covers</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Leaks within the system</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Obstructed access points</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Faulty landing valves</span></li>
</ul>
<p><span style="font-weight: 400;">If a fault is only discovered during an emergency, it can delay firefighting operations and affect the ability of emergency services to tackle a fire effectively.</span></p>
<p><span style="font-weight: 400;">Regular maintenance helps reduce this risk by identifying problems before they impact the performance of the system.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_37 et_pb_row et_flex_row">
<div class="et_pb_column_37 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_17 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">How Dry Riser Maintenance Supports Emergency Response</h2></div></div>
</div>
</div>

<div class="et_pb_row_38 et_pb_row et_flex_row">
<div class="et_pb_column_38 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_20 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">A dry riser allows firefighters to quickly pump water through a building and access upper floors more efficiently.</span></p>
<p><span style="font-weight: 400;">When a dry riser system has been regularly maintained, firefighters can have greater confidence that:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Water will reach the required floors</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Valves will operate correctly</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Connections will be accessible</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The system will hold pressure</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Equipment will function as intended</span></li>
</ul>
<p><span style="font-weight: 400;">Even a small fault can create delays during an emergency. Regular servicing helps ensure the system is ready to support emergency response when required.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_39 et_pb_row et_flex_row">
<div class="et_pb_column_39 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_18 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">The Purpose of Dry Riser Service</h2></div></div>
</div>
</div>

<div class="et_pb_row_40 et_pb_row et_flex_row">
<div class="et_pb_column_40 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_21 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">A professional dry riser inspection focuses on the condition of the system and its components.</span></p>
<p><span style="font-weight: 400;">Inspections are typically carried out every six months and involve checking:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Inlet valves</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Landing valves</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Pipework</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Cabinets and covers</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Signage</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Accessibility</span></li>
</ul>
<p><span style="font-weight: 400;">The aim is to identify visible signs of wear, damage or deterioration that could affect the system's operation.</span></p>
<p><span style="font-weight: 400;">Many issues found during inspections can be resolved before they become larger and more costly problems.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_41 et_pb_row et_flex_row">
<div class="et_pb_column_41 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_19 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Why Dry Riser Testing Is Essential</h2></div></div>
</div>
</div>

<div class="et_pb_row_42 et_pb_row et_flex_row">
<div class="et_pb_column_42 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_22 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Alongside routine inspections, dry riser testing plays an important role in maintaining system reliability.</span></p>
<p><span style="font-weight: 400;">A full pressure test is normally carried out annually to confirm the system remains watertight and capable of operating correctly.</span></p>
<p><span style="font-weight: 400;">During testing, engineers assess:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Pipework integrity</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Valve performance</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Water tightness</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Overall system condition</span></li>
</ul>
<p><span style="font-weight: 400;">This process helps identify faults that may not be visible during a routine inspection.</span></p>
<p><span style="font-weight: 400;">Following successful testing, a certificate of compliance can be issued, providing confirmation that the system has been tested in line with current requirements and a service label is completed inside the dry riser cabinet so any 3rd parties, such as the fire service can see when the last service was carried out.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_43 et_pb_row et_flex_row">
<div class="et_pb_column_43 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_20 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">How Dry Riser Maintenance Is Scheduled</h2></div></div>
</div>
</div>

<div class="et_pb_row_44 et_pb_row et_flex_row">
<div class="et_pb_column_44 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_23 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Dry riser maintenance should be carried out at regular intervals throughout the year to ensure the system remains compliant and ready for use in an emergency. A visual inspection is typically completed every six months, while a full pressure test is carried out annually.</span></p>
<p><span style="font-weight: 400;">As these inspections are six months apart, maintenance is often split across different times of the year. In many cases, the annual pressure test is completed during the summer months when ground conditions are drier. As dry riser systems can hold a significant amount of water, draining the system after testing can be more practical during warmer weather. The six-month visual inspection or minor service is then carried out during the winter period.</span></p>
<p><span style="font-weight: 400;">At <a href="https://thefirepeople.co.uk/about-us/"><strong>The Fire People</strong></a>, we use dedicated job management software to keep track of maintenance schedules and notify clients when inspections and testing become due. This helps ensure dry riser maintenance is completed on time and systems remain compliant throughout the year.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_45 et_pb_row et_flex_row">
<div class="et_pb_column_45 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_21 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">The Cost of Delaying Dry Riser Maintenance</h2></div></div>
</div>
</div>

<div class="et_pb_row_46 et_pb_row et_flex_row">
<div class="et_pb_column_46 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_24 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Many building owners only think about a dry riser when maintenance becomes due or a fault develops.</span></p>
<p><span style="font-weight: 400;">Delaying maintenance can often result in:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">More expensive repairs</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Increased system downtime</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Compliance concerns</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Greater risk of equipment failure</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Potential disruption to building operations</span></li>
</ul>
<p><span style="font-weight: 400;">Addressing minor issues early is usually far more cost-effective than dealing with significant repairs after a fault has developed.</span></p>
<p><span style="font-weight: 400;">Planned maintenance also allows any remedial work to be carried out in a controlled manner rather than as an emergency.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_47 et_pb_row et_flex_row">
<div class="et_pb_column_47 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_22 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Who Is Responsible for Dry Riser Maintenance?</h2></div></div>
</div>
</div>

<div class="et_pb_row_48 et_pb_row et_flex_row">
<div class="et_pb_column_48 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_25 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Responsibility for dry riser maintenance generally sits with:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Property owners</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Landlords</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Facilities managers</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Managing agents</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Duty holders responsible for fire safety</span></li>
</ul>
<p><span style="font-weight: 400;">As dry risers form part of a building's </span><a href="https://thefirepeople.co.uk/fire-risk-assessments/"><b>fire safety measures</b></a><span style="font-weight: 400;">, ensuring they are inspected, tested and maintained is an important part of ongoing compliance and risk management.</span></p>
<p><span style="font-weight: 400;">Working with a competent provider helps ensure all required inspections and testing are carried out correctly and recorded appropriately.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_49 et_pb_row et_flex_row">
<div class="et_pb_column_49 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_23 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Arrange Dry Riser Testing and Maintenance with The Fire People</h2></div></div>
</div>
</div>

<div class="et_pb_row_50 et_pb_row et_flex_row">
<div class="et_pb_column_50 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_26 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Regular dry riser maintenance is one of the simplest ways to help prevent avoidable problems and ensure your fire safety systems remain ready for use.</span></p>
<p><span style="font-weight: 400;">At The Fire People</span><span style="font-weight: 400;">, our experienced engineers provide professional dry riser maintenance, dry riser testing and dry riser inspection services for commercial and residential properties across South Wales. We carry out all work to a high standard and help property owners, landlords and facilities managers keep their systems compliant and fully operational. Our job management software allows us to schedule your maintenance so testing is carried out on time, every time.</span></p>
<p><span style="font-weight: 400;">To discuss your dry riser maintenance requirements or arrange an inspection, </span><a href="https://thefirepeople.co.uk/contact-us/"><b>contact The Fire People today</b></a><span style="font-weight: 400;">.</span></p>
</div></div>
</div>
</div>
</div>]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/how-regular-dry-riser-maintenance-helps-prevent-emergencies/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Fire Safety Assessment: The Importance of Fire Alarms</title>
		<link>https://thefirepeople.co.uk/fire-safety-assessment-the-importance-of-fire-alarms/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fire-safety-assessment-the-importance-of-fire-alarms</link>
					<comments>https://thefirepeople.co.uk/fire-safety-assessment-the-importance-of-fire-alarms/#respond</comments>
		
		<dc:creator><![CDATA[AD Marketing Group]]></dc:creator>
		<pubDate>Wed, 27 May 2026 11:36:01 +0000</pubDate>
				<category><![CDATA[Fire Risk Assessment]]></category>
		<category><![CDATA[Fire Safety]]></category>
		<category><![CDATA[Fire Safety At Work]]></category>
		<category><![CDATA[Fire Training]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1165</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_4 et_pb_section et_section_regular et_flex_section">
<div class="et_pb_row_68 et_pb_row et_flex_row">
<div class="et_pb_column_68 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_36 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><a href="https://thefirepeople.co.uk/fire-alarms/"><b>Fire alarms</b></a><span style="font-weight: 400;"> are one of the most important parts of any fire safety assessment. Whether it is an office, warehouse, retail unit, school, or industrial building, having the right system in place helps protect staff, visitors, customers, and the property itself.</span></p>
<p><span style="font-weight: 400;">At The Fire People, we work with businesses across South Wales, providing professional fire alarm installation, servicing, and ongoing maintenance support. Fire alarm systems are an essential life safety system, they provide an early warning of a fire, thus helping people evacuate safely and reducing the risk of serious damage to buildings and equipment.</span></p>
<p><span style="font-weight: 400;">Many businesses only think about their fire alarm system once something goes wrong or issues are raised during a fire risk assessment. Regular testing and maintenance help ensure the system is working properly and responds when needed.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_69 et_pb_row et_flex_row">
<div class="et_pb_column_69 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_32 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">The Role of Fire Alarms in a Fire Safety Assessment</h2></div></div>
</div>
</div>

<div class="et_pb_row_70 et_pb_row et_flex_row">
<div class="et_pb_column_70 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_37 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">A </span><a href="https://thefirepeople.co.uk/fire-risk-assessments/"><b>Fire Risk Assessment</b></a><span style="font-weight: 400;"> looks at the fire risks within a property and reviews whether the correct safety measures are in place. Fire alarms form a major part of this process.</span></p>
<p><span style="font-weight: 400;">During an assessment, areas commonly reviewed include:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Existing fire alarm systems</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Emergency Lighting</span></li>
<li style="font-weight: 400;" aria-level="1"><a href="https://thefirepeople.co.uk/fire-extinguishers/"><b>Fire Extinguishers</b></a></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Escape routes</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Fire doors</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Electrical risks</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Staff fire procedures</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Maintenance records</span></li>
</ul>
<p><span style="font-weight: 400;">If fire alarms are outdated, damaged, or unsuitable for the building, this can increase the level of risk identified within the assessment.</span></p>
<p><span style="font-weight: 400;">Businesses should not treat fire alarms as something that is installed once and forgotten about. Systems need regular testing and servicing to remain reliable and compliant.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_71 et_pb_row et_flex_row">
<div class="et_pb_column_71 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_33 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Choosing the Right Commercial Fire Alarm System</h2></div></div>
</div>
</div>

<div class="et_pb_row_72 et_pb_row et_flex_row">
<div class="et_pb_column_72 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_38 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">The type of fire detection and alarm system required depends on how the building is used. A residential building, for example, may require a higher level of protection than an office environment due to the increased risk to life.</span></p>
<p><span style="font-weight: 400;">Different levels of protection are referred to as “categories”, which are usually identified during a fire risk assessment.</span></p>
<p><span style="font-weight: 400;">Commercial fire alarms should always be selected based on the individual requirements of the property rather than using the same setup for every building.</span></p>
<h3><b>Conventional Fire Alarm Systems</b></h3>
<p><span style="font-weight: 400;">These systems are commonly used within smaller commercial properties. They divide the building into zones to help identify where an alarm has been triggered.</span></p>
<h3><b>Addressable Fire Alarm Systems</b></h3>
<p><span style="font-weight: 400;">Addressable systems provide more detailed information by identifying the exact detector or device that has been activated. These systems are often used in larger commercial premises.</span></p>
<h3><b>Wireless Fire Alarm Systems</b></h3>
<p><span style="font-weight: 400;">Wireless systems can reduce disruption during installation and are often used in listed buildings or sites where cabling would be difficult.</span></p>
<h3><b>Monitored Fire Alarm Systems</b></h3>
<p><span style="font-weight: 400;">These systems can automatically contact a monitoring centre when activated, helping businesses respond quickly outside of working hours. For higher risk properties, the fire service can also be alerted of a fire alarm activation for their attendance.</span></p>
<p><span style="font-weight: 400;">Choosing the correct category and system type is important for maintaining both safety and compliance within commercial properties.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_73 et_pb_row et_flex_row">
<div class="et_pb_column_73 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_34 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Why Fire Alarm Servicing Matters</h2></div></div>
</div>
</div>

<div class="et_pb_row_74 et_pb_row et_flex_row">
<div class="et_pb_column_74 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_39 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Fire alarm servicing helps ensure systems continue operating correctly over time. Without regular servicing, faults can go unnoticed and components can fail during an emergency.</span></p>
<p><span style="font-weight: 400;">Routine servicing can help identify:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Faulty detectors</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Wiring issues</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Battery failures</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Sounder faults</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">System errors</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Damaged devices</span></li>
</ul>
<p><span style="font-weight: 400;">Regular fire alarm servicing</span> <span style="font-weight: 400;">also helps reduce false alarms, which can disrupt businesses and lead to people becoming less responsive to alarms over time.</span></p>
<p><span style="font-weight: 400;">At The Fire People, we provide fire alarm servicing and fire alarm maintenance South Wales businesses can rely on to help systems remain compliant with current regulations.</span></p>
<p><span style="font-weight: 400;">Our engineers work in line with current British Standards and regularly undertake training to ensure systems are maintained correctly and to the latest version of BS 5839.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_75 et_pb_row et_flex_row">
<div class="et_pb_column_75 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_35 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Fire Alarm Maintenance Helps Prevent Larger Issues</h2></div></div>
</div>
</div>

<div class="et_pb_row_76 et_pb_row et_flex_row">
<div class="et_pb_column_76 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_40 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Poor maintenance can create serious risks for commercial properties. Even a small fault within the system can affect how quickly people are warned during an emergency.</span></p>
<p><span style="font-weight: 400;">Some common issues caused by poor fire alarm maintenance include:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Delayed fire detection</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">False alarms</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Fault warnings being ignored</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Complete system failure</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Increased risk to staff and visitors</span></li>
</ul>
<p><span style="font-weight: 400;">For businesses, false alarms can also lead to unnecessary disruption and lost working time.</span></p>
<p><span style="font-weight: 400;">Regular fire alarm maintenance helps reduce these risks while improving the reliability of the system overall. Ongoing maintenance can also help identify smaller faults early before they develop into more expensive repairs.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_77 et_pb_row et_flex_row">
<div class="et_pb_column_77 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_36 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">How Often Should Fire Alarms Be Checked?</h2></div></div>
</div>
</div>

<div class="et_pb_row_78 et_pb_row et_flex_row">
<div class="et_pb_column_78 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_41 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Fire alarms should be tested regularly to make sure faults are identified early and systems remain operational.</span></p>
<p><span style="font-weight: 400;">This usually includes:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Weekly alarm testing</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Regular visual inspections</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Bi-annual service and maintenance visits</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Keeping maintenance records updated</span></li>
</ul>
<p><span style="font-weight: 400;">Businesses should also make sure faults or warning messages are addressed promptly rather than waiting until the next inspection.</span></p>
<p><span style="font-weight: 400;">Alongside regular testing, staff should understand basic fire procedures through regular </span><a href="https://thefirepeople.co.uk/fire-training/"><b>Fire Training</b></a><span style="font-weight: 400;"> to help improve safety during an evacuation.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_79 et_pb_row et_flex_row">
<div class="et_pb_column_79 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_37 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Fire Alarm Compliance for Businesses</h2></div></div>
</div>
</div>

<div class="et_pb_row_80 et_pb_row et_flex_row">
<div class="et_pb_column_80 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_42 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Under UK fire safety legislation, businesses are responsible for taking reasonable steps to protect people from fire risks. This includes ensuring suitable fire alarm systems are installed and maintained correctly.</span></p>
<p><span style="font-weight: 400;">A fire safety assessment may identify:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Inadequate alarm coverage</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Outdated systems</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Missing detectors</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Poor maintenance records</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Areas requiring upgraded protection</span></li>
</ul>
<p><span style="font-weight: 400;">Ignoring these issues can leave businesses exposed to unnecessary risks and potential enforcement action.</span></p>
<p><span style="font-weight: 400;">Electrical faults also remain one of the leading causes of commercial fires. Carrying out regular </span><a href="https://thefirepeople.co.uk/services/eicr-certificates-for-business/"><b>EICR Certificates for Business</b></a><span style="font-weight: 400;"> can help identify electrical issues before they become fire hazards.</span></p>
<p><span style="font-weight: 400;">Keeping accurate records of servicing and maintenance is equally important, particularly for businesses operating within customer-facing or heavily regulated environments.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_81 et_pb_row et_flex_row">
<div class="et_pb_column_81 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_38 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Professional Fire Alarm Installation in South Wales</h2></div></div>
</div>
</div>

<div class="et_pb_row_82 et_pb_row et_flex_row">
<div class="et_pb_column_82 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_43 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Professional installation helps ensure fire alarms are fitted correctly and positioned in the right areas of the building.</span></p>
<p><span style="font-weight: 400;">Incorrect installation can lead to poor coverage, repeated faults, and systems that are not suitable for the property.</span></p>
<p><span style="font-weight: 400;">When carrying out fire alarm installations, businesses should consider:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Building layout</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Escape routes</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Occupancy levels</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">High-risk areas</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Future building changes</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Integration with other fire safety systems</span></li>
</ul>
<p><span style="font-weight: 400;">At The Fire People, our experienced engineers can design, install, commission, service, and upgrade fire alarm systems for commercial premises across South Wales.</span></p>
<p><span style="font-weight: 400;">We also provide ongoing servicing agreements, including access to 24-hour callouts where required, helping businesses maintain compliance and gain support quickly if issues arise.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_83 et_pb_row et_flex_row">
<div class="et_pb_column_83 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_39 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Supporting Businesses Across South Wales</h2></div></div>
</div>
</div>

<div class="et_pb_row_84 et_pb_row et_flex_row">
<div class="et_pb_column_84 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_44 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">At The Fire People, we support businesses with fire alarm installation, fire alarm servicing, and commercial fire alarms throughout South Wales.</span></p>
<p><span style="font-weight: 400;">Whether you need support with an existing system, a new installation, or a full fire risk assessment, our team can help.</span></p>
<p><span style="font-weight: 400;">We can also provide combined servicing support for both fire alarms and </span><a href="https://thefirepeople.co.uk/emergency-lighting/"><b>Emergency Lighting</b></a><span style="font-weight: 400;"> systems, helping businesses manage fire safety requirements more efficiently.</span></p>
<p><span style="font-weight: 400;">To discuss your fire alarm requirements or arrange a fire safety assessment, </span><a href="https://thefirepeople.co.uk/contact-us/"><b>contact The Fire People today</b></a><span style="font-weight: 400;">.</span></p>
<p>&nbsp;</p>
</div></div>
</div>
</div>
</div>]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/fire-safety-assessment-the-importance-of-fire-alarms/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>What Happens During an EICR Inspection?</title>
		<link>https://thefirepeople.co.uk/what-happens-during-an-eicr-inspection/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=what-happens-during-an-eicr-inspection</link>
					<comments>https://thefirepeople.co.uk/what-happens-during-an-eicr-inspection/#respond</comments>
		
		<dc:creator><![CDATA[AD Marketing Group]]></dc:creator>
		<pubDate>Fri, 01 May 2026 12:55:50 +0000</pubDate>
				<category><![CDATA[EICR]]></category>
		<category><![CDATA[Electrical Safety]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1158</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_6 et_pb_section et_section_regular et_flex_section">
<div class="et_pb_row_106 et_pb_row et_flex_row">
<div class="et_pb_column_106 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_56 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">If you run a business or manage a property, electrical safety is one of those things you know you need to stay on top of. But when it comes to </span><a href="https://thefirepeople.co.uk/services/eicr-certificates-for-business/"><b>EICR testing</b></a><span style="font-weight: 400;">, a lot of people aren’t fully sure what actually happens during the inspection.</span></p>
<p><span style="font-weight: 400;">This guide walks you through it in plain terms, so you know what to expect, how long it takes, and what you’ll get at the end of it.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_107 et_pb_row et_flex_row">
<div class="et_pb_column_107 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_50 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">What is an EICR?</h2></div></div>
</div>
</div>

<div class="et_pb_row_108 et_pb_row et_flex_row">
<div class="et_pb_column_108 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_57 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">An Electrical Installation Condition Report (EICR) is a detailed check of your building’s electrical installation.</span></p>
<p><span style="font-weight: 400;">It examines your fixed wiring, circuits, and key components to ensure everything is safe and working properly. Over time, electrical systems can wear out or develop faults, and an EICR helps catch those issues early.</span></p>
<p><span style="font-weight: 400;">For businesses and landlords, it’s also an important part of staying compliant with safety responsibilities, often alongside other safety checks such as a </span><a href="https://thefirepeople.co.uk/fire-risk-assessments/"><b>fire risk assessment</b></a><span style="font-weight: 400;">.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_109 et_pb_row et_flex_row">
<div class="et_pb_column_109 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_51 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Why EICR Testing Matters</h2></div></div>
</div>
</div>

<div class="et_pb_row_110 et_pb_row et_flex_row">
<div class="et_pb_column_110 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_58 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Electrical issues rarely happen all at once. They tend to build up over time. Worn cables, loose connections, or overloaded circuits can go unnoticed until they cause a bigger problem.</span></p>
<p><span style="font-weight: 400;">Regular EICR testing helps you:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Spot problems early</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Keep your property safe to use</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Stay in line with regulations</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Avoid costly repairs later on</span></li>
</ul>
<p><span style="font-weight: 400;">Testing should be carried out every 5 years to meet legislation.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_111 et_pb_row et_flex_row">
<div class="et_pb_column_111 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_52 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">What Happens During an EICR Inspection?</h2></div></div>
</div>
</div>

<div class="et_pb_row_112 et_pb_row et_flex_row">
<div class="et_pb_column_112 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_59 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">An EICR is a detailed inspection carried out by a qualified electrician. When previous test history is available, only 20% of the circuit will need to be tested but where previous certificates are not available showing which circuits have been tested before, the whole installation will require testing.</span></p>
<ol>
<li><b> Visual checks</b></li>
</ol>
<p><span style="font-weight: 400;">The inspection usually starts with a visual look at the installation.</span></p>
<p><span style="font-weight: 400;">This includes:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Sockets and switches</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Light fittings</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Fuse boards</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Visible wiring</span></li>
</ul>
<p><span style="font-weight: 400;">The electrician is looking for signs of damage, wear, or doesn’t look quite right and may need further investigation.</span></p>
<h3><b>2. Testing the circuits</b></h3>
<p><span style="font-weight: 400;">After that, the circuits are tested to make sure everything is working safely.</span></p>
<p><span style="font-weight: 400;">This involves:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Checking the condition of the wiring</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Testing how circuits perform</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Making sure safety devices operate properly</span></li>
</ul>
<p><span style="font-weight: 400;">Some of this testing is done while the system is live, and some requires the power to be switched off.</span></p>
<p><span style="font-weight: 400;">If circuits are clearly labelled, they can often be tested individually, which helps reduce disruption.</span></p>
<p>&nbsp;</p>
<h3><b>3. Checking key safety components</b></h3>
<p><span style="font-weight: 400;">Certain parts of your electrical system are critical for safety and require close attention during EICR testing.</span></p>
<p><span style="font-weight: 400;">These include:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Earthing and bonding</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Circuit protection</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Distribution boards</span></li>
</ul>
<p><span style="font-weight: 400;">If these aren’t working properly, faults can become dangerous - they can cause injury, damage electrical equipment required for business operations or pose a fire risk.</span></p>
<p>&nbsp;</p>
<h3><b>4. Issues are recorded</b></h3>
<p><span style="font-weight: 400;">If anything is found during the inspection, it’s noted in the report along with what needs to be done.</span></p>
<p><span style="font-weight: 400;">This could be:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Damage to wiring</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Signs of overloading</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Outdated components</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">General wear and tear</span></li>
</ul>
<p><span style="font-weight: 400;">You’ll be given a clear explanation of what’s been found and whether any work is needed.</span></p>
<p>&nbsp;</p>
<h3><b>5. You receive your certificate</b></h3>
<p><span style="font-weight: 400;">At the end of the inspection, you’ll receive your EICR certificate.</span></p>
<p><span style="font-weight: 400;">This outlines:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">What was tested</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The overall condition of your system</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Any issues identified</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Recommended next steps</span></li>
</ul>
<p><span style="font-weight: 400;">It will also confirm whether your installation is considered safe or if further work is required.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_113 et_pb_row et_flex_row">
<div class="et_pb_column_113 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_53 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">What Happens After EICR Testing?</h2></div></div>
</div>
</div>

<div class="et_pb_row_114 et_pb_row et_flex_row">
<div class="et_pb_column_114 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_60 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">What you do next depends on the result.</span></p>
<p><span style="font-weight: 400;">If everything is in good condition, there’s nothing you need to do straight away. You’ll just need to keep track of when your next inspection is due.</span></p>
<p><span style="font-weight: 400;">If issues are found, you’ll be advised on what needs to be fixed. Once any work is completed, your system can be brought back up to a safe standard.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_115 et_pb_row et_flex_row">
<div class="et_pb_column_115 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_54 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">How Long Does EICR Testing Take?</h2></div></div>
</div>
</div>

<div class="et_pb_row_116 et_pb_row et_flex_row">
<div class="et_pb_column_116 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_61 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">The time it takes depends on the size and setup of your property.</span></p>
<p><span style="font-weight: 400;">As a general guide:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Smaller properties may take around half a day</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Larger sites can take a few days</span></li>
</ul>
<p><span style="font-weight: 400;">The number of circuits and how easy they are to access will affect this.</span></p>
<p><span style="font-weight: 400;">Having previous test records can sometimes help reduce the amount of testing needed.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_117 et_pb_row et_flex_row">
<div class="et_pb_column_117 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_55 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">EICR Cost: What Affects It?</h2></div></div>
</div>
</div>

<div class="et_pb_row_118 et_pb_row et_flex_row">
<div class="et_pb_column_118 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_62 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">There isn’t a fixed EICR cost, as it depends on the property.</span></p>
<p><span style="font-weight: 400;">The main factors include:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The number of circuits</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Size of the building</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Number of distribution boards</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Complexity of the electrical installation</span></li>
</ul>
<p><span style="font-weight: 400;">Because of this, quotes are usually tailored to your specific setup.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_119 et_pb_row et_flex_row">
<div class="et_pb_column_119 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_56 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Will It Disrupt Your Business?</h2></div></div>
</div>
</div>

<div class="et_pb_row_120 et_pb_row et_flex_row">
<div class="et_pb_column_120 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_63 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">In most cases, disruption is kept to a minimum.</span></p>
<p><span style="font-weight: 400;">Electricians will:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Work in sections where possible</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Avoid shutting down large areas unnecessarily</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Plan around your working hours where they can</span></li>
</ul>
<p><span style="font-weight: 400;">Clear labelling of circuits can make a big difference here.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_121 et_pb_row et_flex_row">
<div class="et_pb_column_121 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_57 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Do You Need a Qualified Electrician?</h2></div></div>
</div>
</div>

<div class="et_pb_row_122 et_pb_row et_flex_row">
<div class="et_pb_column_122 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_64 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Yes. EICR testing should always be carried out by a qualified and experienced electrician.</span></p>
<p><span style="font-weight: 400;">This ensures:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">The inspection is done properly</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Any risks are identified accurately</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">You receive an industry recognised certificate</span></li>
</ul>
<p><span style="font-weight: 400;">It also helps make sure your property meets current safety standards.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_123 et_pb_row et_flex_row">
<div class="et_pb_column_123 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_58 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Do You Need an EICR?</h2></div></div>
</div>
</div>

<div class="et_pb_row_124 et_pb_row et_flex_row">
<div class="et_pb_column_124 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_65 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">If you’re responsible for a workplace or rental property, it’s something you should have in place.</span></p>
<p><span style="font-weight: 400;">Electrical faults are a common cause of fires and can lead to serious disruption. Regular inspections help you stay ahead of potential problems and keep people safe.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_125 et_pb_row et_flex_row">
<div class="et_pb_column_125 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_59 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Overview</h2></div></div>
</div>
</div>

<div class="et_pb_row_126 et_pb_row et_flex_row">
<div class="et_pb_column_126 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_66 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">An EICR is really just about knowing where you stand. It gives you a clear picture of your electrical system, highlights anything that needs attention, and helps you avoid bigger issues further down the line.</span></p>
<p><span style="font-weight: 400;">If it’s been a while since your last inspection, or you’re not sure when it was done, it’s something which should be arranged. It’s a straightforward way to keep your business safe and compliant without second-guessing anything.</span></p>
<p><span style="font-weight: 400;">At </span><a href="https://thefirepeople.co.uk/"><b>The Fire People</b></a><span style="font-weight: 400;">, we carry out EICR testing across South East Wales, working around your schedule to keep disruption to a minimum and explaining everything clearly along the way. </span></p>
<p><span style="font-weight: 400;">If you’d like to arrange an inspection or get a quote, </span><a href="https://thefirepeople.co.uk/contact-us/"><b>arrange your EICR inspection</b></a><span style="font-weight: 400;"> and we’ll help you get it booked in.</span></p>
</div></div>
<div class="et_pb_module et_pb_button_module_wrapper et_pb_button_1_wrapper"><a class="et_pb_button_1 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module" href="https://thefirepeople.co.uk/contact-us/"><span class="et-pb-parallax-content">Get a quote</span></a></div>
</div>
</div>
</div>]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/what-happens-during-an-eicr-inspection/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>A Business Owner’s Guide to Dry Riser Testing and Maintenance</title>
		<link>https://thefirepeople.co.uk/a-business-owners-guide-to-dry-riser-testing-and-maintenance/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=a-business-owners-guide-to-dry-riser-testing-and-maintenance</link>
					<comments>https://thefirepeople.co.uk/a-business-owners-guide-to-dry-riser-testing-and-maintenance/#respond</comments>
		
		<dc:creator><![CDATA[AD Marketing Group]]></dc:creator>
		<pubDate>Thu, 16 Apr 2026 14:22:16 +0000</pubDate>
				<category><![CDATA[Dry Riser]]></category>
		<category><![CDATA[Fire Safety]]></category>
		<category><![CDATA[Fire Safety At Work]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1138</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_8 et_pb_section et_section_regular et_flex_section">
<div class="et_pb_row_142 et_pb_row et_flex_row">
<div class="et_pb_column_142 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_75 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p>If you’re responsible for a commercial building, keeping a premise’s <strong><a href="https://thefirepeople.co.uk/fire-risk-assessments/">fire safety system</a></strong> fully functioning isn’t optional - it’s a legal requirement. One system in the whole process, often overlooked until it’s needed most, is the <strong><a href="https://thefirepeople.co.uk/dry-riser-testing/">dry riser system</a></strong>.</p>
<p>Dry risers play a vital role in helping fire services respond to emerging fire hazards that arise in multi-storey buildings. Regular maintenance ensures they work as intended in an emergency and keeps your building compliant with current regulations.</p>
<p>The issue is, they’re often out of sight and out of mind until something goes wrong. Regular testing and maintenance help ensure your system works when needed and stays on the right side of regulations.</p>
</div></div>
</div>
</div>

<div class="et_pb_row_143 et_pb_row et_flex_row">
<div class="et_pb_column_143 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_67 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">What Is a Dry Riser System?</h2></div></div>
</div>
</div>

<div class="et_pb_row_144 et_pb_row et_flex_row">
<div class="et_pb_column_144 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_76 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p>A dry riser is a network of pipework that enables fire services to pump water to different floors within a building.</p>
<p>Firefighters connect to an inlet at ground level, which supplies water to outlets on each floor. This means they can access water quickly without having to run hoses through stairwells.</p>
<p>Dry risers are typically installed in buildings over 18 metres, including offices, apartment blocks and larger commercial premises.</p>
</div></div>
</div>
</div>

<div class="et_pb_row_145 et_pb_row et_flex_row">
<div class="et_pb_column_145 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_68 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Dry Riser Testing: What’s Required?</h2></div></div>
</div>
</div>

<div class="et_pb_row_146 et_pb_row et_flex_row">
<div class="et_pb_column_146 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_77 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;"><a href="https://thefirepeople.co.uk/dry-riser-testing/">Dry riser testing</a> is carried out to make sure the system is working as it should.</span></p>
<p><span style="font-weight: 400;">This usually involves:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Six-monthly visual checks, making sure everything is in good condition and easy to access.</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Annual pressure testing confirms that the system can withstand the required pressure without leaks.</span></li>
</ul>
<p><span style="font-weight: 400;">Keeping on top of this helps pick up issues early and avoids problems later on.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_147 et_pb_row et_flex_row">
<div class="et_pb_column_147 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_69 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Dry Riser Inspection: What Does It Involve?</h2></div></div>
</div>
</div>

<div class="et_pb_row_148 et_pb_row et_flex_row">
<div class="et_pb_column_148 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_78 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Inspections focus on the system's condition and whether it’s ready for use.</span></p>
<p><span style="font-weight: 400;">That includes checking:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Inlet and outlet valves</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Caps and seals</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Any signs of corrosion or damage</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">That access points aren’t blocked</span></li>
</ul>
<p><span style="font-weight: 400;">It’s about making sure everything is where it should be and works when needed.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_149 et_pb_row et_flex_row">
<div class="et_pb_column_149 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_70 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">How Often Should Dry Riser Maintenance Be Carried Out?</h2></div></div>
</div>
</div>

<div class="et_pb_row_150 et_pb_row et_flex_row">
<div class="et_pb_column_150 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_79 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">Dry riser maintenance should be carried out regularly rather than waiting for something to go wrong.</span></p>
<p><span style="font-weight: 400;">As a guide:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Every 6 months for visual checks (minor service)</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Once a year for full pressure testing (major service)</span></li>
</ul>
<p><span style="font-weight: 400;">In most cases, this responsibility sits with the building owner or whoever is responsible for fire safety on site.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_151 et_pb_row et_flex_row">
<div class="et_pb_column_151 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_71 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Common Issues Found During Dry Riser Servicing</h2></div></div>
</div>
</div>

<div class="et_pb_row_152 et_pb_row et_flex_row">
<div class="et_pb_column_152 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_80 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">During servicing, it’s common to come across issues that aren’t obvious day to day, such as:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Leaks in the pipework</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Damaged or missing caps</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Corrosion affecting performance</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Blocked access points</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Faulty valves or connections</span></li>
</ul>
<p><span style="font-weight: 400;">Dealing with these early helps avoid bigger problems and keeps the system reliable.</span></p>
</div></div>
</div>
</div>

<div class="et_pb_row_153 et_pb_row et_flex_row">
<div class="et_pb_column_153 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_72 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Dry Riser Testing South Wales: Staying Compliant</h2></div></div>
</div>
</div>

<div class="et_pb_row_154 et_pb_row et_flex_row">
<div class="et_pb_column_154 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_81 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p>If the building you're located in has a dry riser, it needs to be regularly maintained in line with current standards. That responsibility usually belongs to the premises owner.</p>
<p>Working with a qualified provider ensures testing is carried out efficiently and correctly, issues are dealt with promptly, and your system remains compliant.</p>
</div></div>
</div>
</div>

<div class="et_pb_row_155 et_pb_row et_flex_row">
<div class="et_pb_column_155 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_heading_73 et_pb_heading et_pb_module et_flex_module"><div class="et_pb_heading_container"><h2 class="et_pb_module_header">Book Your Dry Riser Testing and Maintenance</h2></div></div>
</div>
</div>

<div class="et_pb_row_156 et_pb_row et_flex_row">
<div class="et_pb_column_156 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone">
<div class="et_pb_text_82 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><p>Keeping your dry riser system properly tested and maintained is essential to ensure it performs as intended in the event of a fire. Regular testing checks the condition of the pipework, valves and inlets, helping to pick up issues early before they become a risk.</p>
<p>At <strong><a href="https://thefirepeople.co.uk/">The Fire People</a></strong>, we provide professional dry riser testing, inspections and maintenance for commercial properties across South Wales. Our experienced engineers carry out all work in line with current standards, giving you confidence that your system is compliant and ready for use.</p>
<p>If you need to arrange dry riser testing or require advice on your system, please <strong><a href="https://thefirepeople.co.uk/contact-us/">contact our team today</a></strong>, and we will be happy to help.</p>
</div></div>
<div class="et_pb_module et_pb_button_module_wrapper et_pb_button_3_wrapper"><a class="et_pb_button_3 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module" href="https://thefirepeople.co.uk/contact-us/"><span class="et-pb-parallax-content">Get a quote</span></a></div>
</div>
</div>
</div>]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/a-business-owners-guide-to-dry-riser-testing-and-maintenance/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Fire Safety Risk Assessments and Training: Essential for Ensuring a Safe Workspace</title>
		<link>https://thefirepeople.co.uk/fire-safety-risk-assessments-and-training-essential-for-ensuring-a-safe-workspace/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fire-safety-risk-assessments-and-training-essential-for-ensuring-a-safe-workspace</link>
					<comments>https://thefirepeople.co.uk/fire-safety-risk-assessments-and-training-essential-for-ensuring-a-safe-workspace/#respond</comments>
		
		<dc:creator><![CDATA[The Fire People]]></dc:creator>
		<pubDate>Thu, 05 Mar 2026 14:39:32 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1127</guid>

					<description><![CDATA[Fire safety management is a routine requirement for workplaces across all sectors in the UK. Whether in buildings, equipment, or daily operations, there are numerous potential ignition sources and combustible materials that can endanger the workplace. To mitigate these risks, organisations and businesses rely on regular fire risk assessments and consistent employee training. A fire [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph" style="font-size:15px">Fire safety management is a routine requirement for workplaces across all sectors in the UK. Whether in buildings, equipment, or daily operations, there are numerous potential ignition sources and combustible materials that can endanger the workplace. To mitigate these risks, organisations and businesses rely on regular fire risk assessments and consistent employee training.</p>



<p class="wp-block-paragraph" style="font-size:15px">A <a href="https://thefirepeople.co.uk/fire-risk-assessments/"><strong>fire safety risk assessment</strong></a> provides an in-depth and professional examination of a workplace, identifying hazards within commercial premises. In association, employees of a business often undergo training to become familiar with procedures that serve to protect life and property. When combined, these measures form a practical framework for workplace fire safety.</p>



<p class="wp-block-paragraph"></p>



<p class="has-medium-font-size wp-block-paragraph"><br><strong>Why Fire Safety Risk Assessments Matter in Every Workplace</strong></p>



<p class="has-small-font-size wp-block-paragraph"><br>A Fire safety risk assessment can take many forms, but in essence, the procedure is a systematic review of a premises to identify fire hazards. In addition, the assessment seeks to find who may be at risk while evaluating existing control measures.</p>



<p class="wp-block-paragraph" style="font-size:14px">As workplaces evolve, resulting in staff changes, layout alterations, and new equipment, more risks are likely to arise. Regular reviews ensure fire safety measures remain up to date.<br>For larger organisations or complex sites, a commercial fire risk assessment provides clear evidence of the potential risks that must be addressed. Reviewing fire risk assessments annually enables businesses to monitor risk and plan improvements where required.</p>



<p class="has-medium-font-size wp-block-paragraph"><strong>Legal Responsibilities of Employers Under UK Fire Safety Law</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">The Regulatory Reform (Fire Safety) Order 2005 establishes the legal framework for fire safety in non-domestic premises. The most senior or responsible person, either the employer or building owner, must take certain steps to reduce the likelihood of a fire risk in order to protect occupants. As it’s illegal to complete a fire risk assessment if you are not suitably qualified, knowledgable and experienced, most business owners commission a life safety assessor to carry an assessment out on their behalf.</p>



<p class="wp-block-paragraph" style="font-size:14px">Key responsibilities expected to be handled include conducting a fire safety risk assessment, maintaining escape routes, providing fire detection systems and firefighting equipment, and ensuring employees receive training and clear instructions to follow in a dangerous situation.</p>



<p class="wp-block-paragraph" style="font-size:14px">To support compliance, businesses often work with fire safety specialists for equipment servicing, assessments, and training.</p>



<p class="has-medium-font-size wp-block-paragraph"><strong>What Is Included in a Fire Risk Assessment for Commercial Premises?</strong></p>



<p class="wp-block-paragraph" style="font-size:14px"><br>A fire risk assessment for commercial premises follows a structured approach to evaluate hazards and existing safeguards.</p>



<p class="wp-block-paragraph" style="font-size:14px">This typically includes:</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Identification of fire hazards</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">Review of ignition sources, combustible materials, and oxygen supply.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Identification of people at risk</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">Consideration of employees, visitors, contractors, and individuals requiring assistance during evacuation.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Assessment of existing fire precautions</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">Inspection of alarms, extinguishers, emergency lighting, signage, and escape routes.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Recording findings and recommended actions</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">Documentation of improvements required and prioritisation of actions.</p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>Review and update</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">Periodic reassessment and review following significant changes to the premises.</p>



<p class="wp-block-paragraph" style="font-size:14px">A comprehensive fire safety assessment ensures businesses are aware of current risk levels and maintain appropriate measures.</p>



<p class="wp-block-paragraph" style="font-size:14px"></p>



<p class="wp-block-paragraph" style="font-size:14px"><strong>What Fire Extinguisher Do I Need for My Workplace?</strong></p>



<p class="wp-block-paragraph"></p>



<div class="wp-block-group is-layout-constrained wp-block-group-is-layout-constrained">
<p class="wp-block-paragraph" style="font-size:14px">The selection of <a href="https://thefirepeople.co.uk/risk-assessment-in-winter-are-your-fire-extinguishers-fit-for-cold-weather/"><strong>fire extinguishers for the workplace</strong></a> should reflect the fire risks likely to be identified within the premises. The question “what fire extinguisher do I need” is addressed through the careful consideration of equipment, materials, and workplace activities.</p>



<p class="wp-block-paragraph" style="font-size:14px">Common extinguisher types include:</p>



<ul class="wp-block-list">
<li style="font-size:14px">Water extinguishers for combustible materials such as wood and paper</li>



<li style="font-size:14px">Foam extinguishers for solid combustibles and flammable liquids</li>



<li style="font-size:14px">CO₂ extinguishers for electrical equipment</li>



<li style="font-size:14px">Dry powder extinguishers for multi-risk environments</li>



<li style="font-size:14px">Wet chemical extinguishers for cooking oil and fat hazards</li>
</ul>



<p class="wp-block-paragraph" style="font-size:14px">To find the right fit, a fire risk assessment determines the appropriate fire extinguishers, locations, and coverage to protect against potential hazards.</p>



<p class="wp-block-paragraph"></p>



<p class="has-medium-font-size wp-block-paragraph"><strong>The Importance of Fire Safety Training for Employees</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">Fire safety training relies on employee participation and awareness. Training provides staff with a clear understanding of fire safety measures, evacuation procedures, alarm systems, and workplace fire hazards.</p>



<p class="wp-block-paragraph" style="font-size:14px">Typical training content includes identifying fire risks, following evacuation procedures, raising alarms, and understanding fire warden responsibilities. In addition, employee awareness of extinguisher use helps reinforce a safe and appropriate response during an incident and provides attendees with confidence around fire safety in the workplace.</p>



<p class="wp-block-paragraph" style="font-size:14px">Offering consistent training supports orderly evacuation and helps ensure procedures are followed should an incident occur.</p>



<p class="wp-block-paragraph"></p>



<p class="has-medium-font-size wp-block-paragraph"><strong>How Often Should Training Be Reviewed</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">Training programmes should be scheduled regularly to maintain effectiveness. It is common for workplaces to change, for staff to come and go, and for procedures to require adjustments in the time in between.</p>



<p class="wp-block-paragraph" style="font-size:14px">Frequent practices include induction training for new employees, refresher sessions, and scheduled fire drills to reinforce evacuation procedures.</p>



<p class="wp-block-paragraph" style="font-size:14px">Regular reviews help maintain familiarity with safety measures and ensure fire safety remains a constant in the workplace.</p>



<p class="wp-block-paragraph"></p>



<p class="has-medium-font-size wp-block-paragraph"><strong>Overview</strong></p>



<p class="wp-block-paragraph" style="font-size:14px">Workplace fire safety is contingent on consistent assessment, appropriate equipment, and informed employees. A fire safety risk assessment identifies hazards and informs control measures, while training provides employees with the knowledge needed to respond safely and follow established procedures.&nbsp;</p>



<p class="wp-block-paragraph" style="font-size:14px">Many businesses choose to work with specialist providers such as <a href="https://thefirepeople.co.uk/"><strong>The Fire People</strong></a> to support assessment, equipment provision, and staff training. Such offerings help maintain consistent fire safety standards across premises.<br>The Fire People can provide tailored fire safety risk assessments, training, and support to help organisations maintain safe and compliant workplaces. <a href="https://thefirepeople.co.uk/contact-us/"><strong>Contact the team</strong></a> to discuss your requirements or arrange an assessment.<br><br><br><br><br></p>
</div>
]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/fire-safety-risk-assessments-and-training-essential-for-ensuring-a-safe-workspace/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Risk Assessment in Winter: Are Your Fire Extinguishers Fit for Cold Weather?</title>
		<link>https://thefirepeople.co.uk/risk-assessment-in-winter-are-your-fire-extinguishers-fit-for-cold-weather/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=risk-assessment-in-winter-are-your-fire-extinguishers-fit-for-cold-weather</link>
					<comments>https://thefirepeople.co.uk/risk-assessment-in-winter-are-your-fire-extinguishers-fit-for-cold-weather/#respond</comments>
		
		<dc:creator><![CDATA[AD Marketing Group]]></dc:creator>
		<pubDate>Fri, 23 Jan 2026 09:59:48 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1051</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_10 et_pb_section et_section_regular et_block_section"><div class="et_pb_row_158 et_pb_row et_block_row"><div class="et_pb_column_158 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough"><div class="et_pb_text_84 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module"><div class="et_pb_text_inner"><p><!-- divi:image {"id":1053,"sizeSlug":"large","linkDestination":"none","className":"is-style-default"} --></p>
<figure class="wp-block-image size-large is-style-default"></figure>
<p><!-- /divi:image --></p>
<p><span style="font-weight: 400;">When people think about winter risks, their concerns tend to focus on frozen pipes, heating issues, and slippery walkways. However, very few think about </span><a href="https://thefirepeople.co.uk/fire-extinguishers/"><b>fire extinguishers</b></a><span style="font-weight: 400;">.</span></p>
<p><span style="font-weight: 400;">But nearly every winter, issues with extinguishers recur. Many are in date, serviced and correctly mounted, </span><span style="font-weight: 400;">yet many are not protected from the elements which can make them unreliable</span><span style="font-weight: 400;">.</span></p>
<p><span style="font-weight: 400;">The truth of the matter is that many extinguishers fail to work in </span><span style="font-weight: 400;">very </span><span style="font-weight: 400;">cold temperatures, becoming particularly problematic in buildings that are unheated for sustained periods. If ever a fire were to start and the extinguisher failed to discharge, the situation could escalate very quickly.</span></p>
<p><span style="font-weight: 400;">Our team works in accordance with British Standards and assesses the possibility of changing environments when installing fire fighting equipment. We offer a range of extinguishers containing low freeze additives to prevent the contents freezing, fire extinguisher covers and fire extinguisher cabinets.</span></p>
<p>&nbsp;</p>
<p><!-- divi:heading --></p>
<h2 class="wp-block-heading"><strong>Why Cold Weather Affects Fire Extinguishers</strong></h2>
<p><span style="font-weight: 400;">What many fail to realise about extinguishers is that most are designed to operate at temperatures above 5°C, as indicated by manufacturer guidance and information printed on the equipment. </span></p>
<p><!-- /divi:heading --></p>
<p><span style="font-weight: 400;">If an extinguisher is stored in a location that drops below 5°C, the contents can freeze, thicken or lose pressure. As a result, when used, an extinguisher may fail to discharge when it is most needed.</span></p>
<p><span style="font-weight: 400;">Even if serviced recently, an extinguisher may fail due to environmental factors. While servicing ensures an extinguisher is functioning on the day it is checked, it does not protect it from prolonged exposure to cold conditions </span><span style="font-weight: 400;">but fire extinguisher covers and cabinets will help to protect equipment from the elements.</span><span style="font-weight: 400;">  </span></p>
<p>&nbsp;</p>
<p><!-- divi:heading --></p>
<h2 class="wp-block-heading"><strong>Fire Extinguishers in Unheated Building</strong><br /><span style="white-space: normal; caret-color: #000000; color: #000000; font-weight: normal;"></span></h2>
<p>It is often the case that extinguishers are installed outdoors or in areas without adequate heating. Construction sites and buildings such as warehouses, garages, and storage units are common examples.</p>
<p><!-- /divi:heading --></p>
<p>Even commercial premises can experience low temperatures due to open doors and windows, heating being switched off overnight, and poor insulation.</p>
<p>These spaces often include electrical equipment, machinery, and packaging. If a fire were to start, the consequences could be dire if nearby extinguishers fail to work.</p>
<p>&nbsp;</p>
<p><!-- divi:heading --></p>
<h2 class="wp-block-heading"><strong>The Risks of Frozen or Partially Frozen Extinguishers</strong></h2>
<p><span style="font-weight: 400;">Having the correct</span> <span style="font-weight: 400;">extinguisher is crucial for maintaining service, depending on the location where the equipment is stored. For example, water spray, water mist, foam, and some wet chemical extinguishers are not suitable for use below 5°C. If the extinguisher were to freeze or become too thick, it might fail to discharge when required.</span></p>
<p>&nbsp;</p>
<p><!-- /divi:heading --></p>
<p><span style="font-weight: 400;">Dry powder extinguishers are more suitable for low-temperature settings, often rated to operate at temperatures of -20°C or lower. Despite this, elements such as frost can affect components of extinguishers, including handles, valves, and pressure gauges. </span></p>
<p><span style="font-weight: 400;">During fire risk assessments, extinguishers may appear visually serviceable while internal components are frozen or seized, preventing them from discharging correctly. Pins can be difficult to remove, and handles may fail to operate, leaving extinguishers inoperable when they are needed most.</span></p>
<p>&nbsp;</p>
<p><!-- divi:heading --></p>
<h2 class="wp-block-heading"><strong>Why Winter Is a Critical Time for Fire Risk Assessments</strong></h2>
<p><a href="https://thefirepeople.co.uk/fire-risk-assessments/"><b>Fire risk assessments</b></a><span style="font-weight: 400;"> should be carried out frequently, but winter is a time when risks often change.</span></p>
<p><!-- /divi:heading --></p>
<p><span style="font-weight: 400;">As the seasons move on, the way a building is utilised and heated often changes too. Buildings that function well in summer can become cold, damp, and poorly ventilated in winter.</span></p>
<p><span style="font-weight: 400;">Heating is often turned off overnight, doors and windows may be left open, and some areas of a building can remain unheated for long periods. This highlights the need for seasonal fire risk assessments to ensure fire safety measures remain effective.</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><!-- divi:heading --></p>
<h2 class="wp-block-heading"><strong>The Real-World Consequences of Equipment Failing</strong></h2>
<p><span style="font-weight: 400;">False confidence is often the biggest risk, especially when it comes to fire extinguishers and their use in an emergency. </span></p>
<p>&nbsp;</p>
<p><!-- /divi:heading --></p>
<p><span style="font-weight: 400;">Businesses may be lulled into a false sense of confidence, even when extinguishers are in date, and a fire risk assessment has been conducted. However, if equipment has been exposed to freezing conditions, it may fail to operate in a high-pressure situation.</span></p>
<p><span style="font-weight: 400;">Luckily, such dangers can be prevented if the right precautions are in place. </span><span style="font-weight: 400;">Choosing the right extinguishers, installing them in a suitable location, and protecting them from freezing temperatures can reduce the likelihood of failure to discharge.</span></p>
<p>&nbsp;</p>
<p><strong>Need help checking your winter fire safety?</strong></p>
<p><span style="font-weight: 400;">If there is any doubt over your fire extinguisher’s suitability for cold conditions or if you require a fire risk assessment, </span><a href="https://thefirepeople.co.uk/"><b>The Fire People</b></a><span style="font-weight: 400;"> can help. Providing </span><a href="https://thefirepeople.co.uk/fire-training/"><b>fire safety training</b></a><span style="font-weight: 400;">, equipment and electrical services for businesses, landlords and commercial premises, The Fire People deliver clear advice and reliable solutions you can trust.</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><!-- divi:heading {"level":3} --><!-- /divi:heading --></p>
<p><a href="https://thefirepeople.co.uk/contact-us/"><b>Contact The Fire People today</b></a><span style="font-weight: 400;"> to discuss safety precautions or arrange a site visit. </span></p>
</div></div></div></div></div>]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/risk-assessment-in-winter-are-your-fire-extinguishers-fit-for-cold-weather/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Fire Safety Signage: What EveryWorkplace Needs to Know</title>
		<link>https://thefirepeople.co.uk/fire-safety-signage-what-everyworkplace-needs-to-know/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=fire-safety-signage-what-everyworkplace-needs-to-know</link>
					<comments>https://thefirepeople.co.uk/fire-safety-signage-what-everyworkplace-needs-to-know/#respond</comments>
		
		<dc:creator><![CDATA[AD Marketing Group]]></dc:creator>
		<pubDate>Thu, 27 Nov 2025 10:27:38 +0000</pubDate>
				<category><![CDATA[Uncategorized]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1031</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_12 et_pb_section et_section_regular et_block_section"><div class="et_pb_row_160 et_pb_row et_block_row"><div class="et_pb_column_160 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough"><div class="et_pb_text_86 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><h2>Fire Safety Signage: What Every Workplace Needs to Know</h2>
<p><span style="font-weight: 400;">When most people think of fire safety, they picture extinguishers, alarms and emergency exits.</span></p>
<p><span style="font-weight: 400;">But one of the simplest and most important parts of workplace safety is often overlooked:<br />signage. Fire safety signage plays a vital role in guiding people to safety and keeping you<br />compliant with regulations.</span></p>
<p><span style="font-weight: 400;">From fire exit signs to fire door notices, having the right signs in the right places can make a huge difference in an emergency. Here’s what every business should know.</span></p>
<h2>Why Fire Safety Signage Matters</h2>
<p>Fire safety signage is more than a tick-box exercise. It’s a legal requirement under the <a href="https://www.legislation.gov.uk/uksi/1996/341/contents">Health and Safety (Safety Signs and Signals) Regulations 1996,</a> which state that workplaces must have clear, compliant signs indicating exits, fire-fighting equipment and mandatory actions.</p>
<p>These signs provide critical direction when it matters most. In low light or smoke, people rely on <a href="https://thefirepeople.co.uk/emergency-lighting/">illuminated exit signs</a> to find the safest way out. Fire door signs remind staff to keep doors closed, a simple action that can slow the spread of smoke and flames and save lives.</p>
<p>Regularly checking and maintaining your signage ensures your safety systems are doing their job when they’re needed most.</p>
<p><span style="font-weight: 400;"></span><b style="color: #3c3c3b; font-size: 26px;">Types of Fire Safety Signs in the Workplace</b></p>
<p><span style="font-weight: 400;">Every workplace is different, but the main types of fire safety signage remain the same. The four key categories each have a specific purpose and colour code:</span></p>
<p><span style="font-weight: 400;">● Fire exit signs (green): Show the quickest and safest escape route during an<br />evacuation.<br />● Fire door signs (blue): Usually say “Fire Door Keep Shut” or “Keep Locked Shut”,<br />reminding people of essential safety actions.<br />● Fire equipment signs (red): Indicate where extinguishers, alarms or hoses are located.<br />● Prohibition and warning signs (red or yellow): Highlight actions that must not be<br />taken, such as blocking exits or smoking near flammable materials.</span></p>
<p><span style="font-weight: 400;">All fire safety signage should comply with BS EN ISO 7010 standards, which ensure symbols<br />are consistent and universally understood. </span></p>
<p><span style="font-weight: 400;">If you haven’t checked your signage recently, it’s worth referring back to your latest <a href="https://thefirepeople.co.uk/fire-risk-assessments/">fire risk</a><br /><a href="https://thefirepeople.co.uk/fire-risk-assessments/">assessment</a> or reviewing your fire risk assessment.</span><span style="font-weight: 400;"></span></p>
<h2>Common Fire Signage Mistakes Businesses Make</h2>
<p><span style="font-weight: 400;">Even well-prepared workplaces can get fire signage wrong. Common problems include faded or damaged signs, inconsistent designs, incorrect placement or non-compliant symbols. Small mistakes like these might not seem serious day to day but can cause confusion and delay evacuation times when it matters most.</span></p>
<p><span style="font-weight: 400;">To stay compliant, businesses should regularly review their signage and look out for:</span></p>
<p><span style="font-weight: 400;">● Missing or outdated signs after layout or refurbishment changes<br />● Obstructed signage or routes that aren’t clearly visible<br />● Mismatched or outdated designs that don’t meet current standards</span></p>
<p><span style="font-weight: 400;">We covered similar issues in our blog on <a href="https://thefirepeople.co.uk/common-fire-risk-issues/">common fire risk assessment</a> problems, which<br />highlights the importance of keeping every part of your fire safety regime up to date.</span></p>
<ul></ul>
<h2><b>Fire Safety Signage Regulations and Compliance</b></h2>
<p>Fire safety signage should form part of your overall <a href="https://thefirepeople.co.uk/fire-risk-assessments/">fire risk assessment</a>. The “Responsible<br />Person” should check that all required signs are in place, clearly visible and correctly located.</p>
<p>Exit routes must be marked, fire equipment should be easy to identify and <a href="https://thefirepeople.co.uk/emergency-lighting/">emergency lighting</a> should be sufficient to keep signs visible during a power failure.<br />Martyn’s Law, which is currently under development, will place even greater focus on<br />preparedness and emergency planning. It will make it more important than ever for businesses to ensure signage supports evacuation procedures and helps staff understand what to do in an emergency.</p>
<ul></ul>
<h2><b>Keeping Signage Up to Date</b></h2>
<p><span style="font-weight: 400;">Workplaces change over time. Layouts are updated, new equipment is installed and rooms are repurposed. Every time something changes, your signage plan should be reviewed. It’s good practice to check all fire safety signage during routine maintenance or when when working through your <a href="https://thefirepeople.co.uk/fire-risk-assessments/">fire risk assessment</a> Action Plan.</span><span style="font-weight: 400;">If any signs are damaged, outdated or no longer relevant, replace them as soon as possible.</span></p>
<ul></ul>
<h2>Stay Safe and Compliant</h2>
<p>Clear, compliant signage can make all the difference in an emergency. It protects staff, visitors and your business.</p>
<p>If you’re unsure whether your signage meets current standards, or you’d like to arrange a fire safety signage review, <a href="https://thefirepeople.co.uk/contact-us/">get in touch with The Fire People</a>.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div></div><div class="et_pb_module et_pb_button_module_wrapper et_pb_button_5_wrapper"><a class="et_pb_button_5 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module" href="https://thefirepeople.co.uk/contact-us/"><span class="et-pb-parallax-content">Get a quote</span></a></div>
</div></div></div>]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/fire-safety-signage-what-everyworkplace-needs-to-know/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>6 Common Issues Fire Risk Assessments Often Uncover</title>
		<link>https://thefirepeople.co.uk/common-fire-risk-issues/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=common-fire-risk-issues</link>
					<comments>https://thefirepeople.co.uk/common-fire-risk-issues/#respond</comments>
		
		<dc:creator><![CDATA[AD Marketing Group]]></dc:creator>
		<pubDate>Tue, 28 Oct 2025 14:26:21 +0000</pubDate>
				<category><![CDATA[Fire Risk Assessment]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=1014</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_14 et_pb_section et_section_regular et_block_section"><div class="et_pb_row_162 et_pb_row et_block_row"><div class="et_pb_column_162 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough"><div class="et_pb_text_88 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module"><div class="et_pb_text_inner"><p><span style="font-weight: 400;">We carry out a lot of </span><a href="https://thefirepeople.co.uk/fire-risk-assessments/"><span style="font-weight: 400;">Fire Risk Assessments</span></a><span style="font-weight: 400;"> across different industries, and certain issues come up again and again.</span></p>
<p><span style="font-weight: 400;">Some are small. Some are serious. All of them could be a problem if there’s ever a fire on site.</span></p>
<p><span style="font-weight: 400;">If you’re wondering whether your workplace is on top of its fire safety, this might be a useful checklist.</span></p>
<h2><b>Do I legally need a Fire Risk Assessment</b></h2>
<p><span style="font-weight: 400;">If you’re responsible for a building that’s used for business, a Fire Risk Assessment isn’t optional. It’s a legal requirement under the Regulatory Reform (Fire Safety) Order 2005.</span></p>
<p><span style="font-weight: 400;">That includes offices, warehouses, shops, communal areas in flats, and anywhere the public has access to. It’s the duty of the “Responsible Person” to make sure an assessment is carried out by someone competent and qualified.</span></p>
<p><span style="font-weight: 400;">The assessment should be reviewed regularly and updated if anything changes, like a new layout, different occupancy, or after a fire safety incident.</span></p>
<p><span style="font-weight: 400;">Failing to have a suitable and sufficient assessment can lead to enforcement notices, fines, or prosecution.</span></p>
<h2><b>Fire Alarms</b></h2>
<p><span style="font-weight: 400;">In most reports, either the alarm hasn’t been installed at all, or no one’s keeping records of the weekly testing.</span></p>
<p><span style="font-weight: 400;">What to check:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Do you have a <a href="https://thefirepeople.co.uk/fire-alarms/">fire alarm system</a></span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Is it tested weekly</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Are you recording and storing those checks</span></li>
</ul>
<h2><b>Fire Extinguishers</b></h2>
<p><span style="font-weight: 400;">We find extinguishers missing from where they should be or with no ID signs above them. That means in a panic, someone might grab the wrong one or not find one at all.</span></p>
<p><span style="font-weight: 400;">What to check:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Are <a href="https://thefirepeople.co.uk/fire-extinguishers/">extinguishers</a> in their correct locations</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Are ID signs in place and visible</span></li>
</ul>
<h2><b>Emergency Lighting</b></h2>
<p><span style="font-weight: 400;">When emergency lights are missing or not tested, evacuation becomes harder. That’s a big risk.</span></p>
<p><span style="font-weight: 400;">What to check:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Do you have<a href="https://thefirepeople.co.uk/emergency-lighting/"> emergency lighting</a></span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Has it been tested</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Are records stored properly</span></li>
</ul>
<h2><b>PAT Testing (Portable Appliance Testing)</b></h2>
<p><span style="font-weight: 400;">It’s common to find PAT testing either hasn’t been done at all or has only been done halfway. We also see staff using personal appliances like kettles or heaters that haven’t been tested.</span></p>
<p><span style="font-weight: 400;">What to check:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Is <a href="https://thefirepeople.co.uk/pat-testing/">PAT testing</a> up to date for all electrical items</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Are personal appliances allowed on site, and are they tested</span></li>
</ul>
<h2><b>Fire Training</b></h2>
<p><span style="font-weight: 400;">A lot of businesses haven’t done any fire training or did it years ago and haven’t refreshed it. Even the best equipment won’t help if people don’t know what to do.</span></p>
<p><span style="font-weight: 400;">What to check:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Has everyone had basic <a href="https://thefirepeople.co.uk/fire-training/">fire awareness training</a></span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Are new starters included</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Do you refresh it regularly</span></li>
</ul>
<h3><b>The Easy Stuff That Still Gets Missed</b><b><br /></b><span style="font-weight: 400;"> </span></h3>
<p><span style="font-weight: 400;">These are things we flag all the time:</span></p>
<ul>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Overloaded extension leads</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Combustible items stored in plant rooms or under stairs</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Open element heaters</span></li>
<li style="font-weight: 400;" aria-level="1"><span style="font-weight: 400;">Fire doors blocked or missing signage like "Keep Clear", "Keep Closed" etc</span></li>
</ul>
<p><span style="font-weight: 400;">These don’t take long to sort but if something did go wrong, they’d become a problem fast.</span></p>
<h3><b>Final thought</b></h3>
<p><span style="font-weight: 400;">FRAs aren’t just about ticking boxes. They’re about spotting problems before they become serious. If you’ve had one done and haven’t acted on it, or haven’t had one at all, now’s a good time.</span></p>
<p><span style="font-weight: 400;">If you need help with your next fire risk assessment or you’re not sure where to start, </span><a href="https://thefirepeople.co.uk/contact-us/"><span style="font-weight: 400;">get in touch</span></a><span style="font-weight: 400;">.</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div></div></div></div></div>]]></content:encoded>
					
					<wfw:commentRss>https://thefirepeople.co.uk/common-fire-risk-issues/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Do I need an EICR?</title>
		<link>https://thefirepeople.co.uk/do-i-need-an-eicr/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=do-i-need-an-eicr</link>
					<comments>https://thefirepeople.co.uk/do-i-need-an-eicr/#respond</comments>
		
		<dc:creator><![CDATA[The Fire People]]></dc:creator>
		<pubDate>Fri, 12 Jul 2024 13:43:15 +0000</pubDate>
				<category><![CDATA[EICR]]></category>
		<category><![CDATA[Electrical Safety]]></category>
		<category><![CDATA[Fire Safety]]></category>
		<category><![CDATA[Fire Safety At Work]]></category>
		<guid isPermaLink="false">https://thefirepeople.co.uk/?p=557</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section_16 et_pb_section et_section_regular et_block_section"><div class="et_pb_row_164 et_pb_row et_block_row"><div class="et_pb_column_164 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough"><div class="et_pb_text_90 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module"><div class="et_pb_text_inner"><h2 data-start="157" data-end="178">Do I need an EICR?</h2>
<p data-start="180" data-end="330">Formerly known as a periodic inspection, an EICR (Electrical Installation Condition Report) is a five-yearly test of your electrical installation.</p>
<h3 data-start="332" data-end="357">Why an EICR matters</h3>
<p data-start="358" data-end="686">As a business owner or landlord, you have a legal duty to ensure employees, customers and tenants are safe. Any issues with electric wiring, circuits, or accessories such as sockets have the potential to cause electric shocks and can cause fires. Ensuring your installation is in good order is vital to prevent such incidents.</p>
<p data-start="688" data-end="885">If you’re unsure how this fits into your wider compliance duties, you can read more about our <a data-start="782" data-end="884" rel="noopener" target="_new" class="decorated-link" href="https://thefirepeople.co.uk/services/eicr-certificates-for-business/">EICR Certificates for Business<span aria-hidden="true" class="ms-0.5 inline-block align-middle leading-none"><svg width="20" height="20" viewbox="0 0 20 20" fill="currentColor" xmlns="http://www.w3.org/2000/svg" data-rtl-flip="" class="block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]"><path d="M14.3349 13.3301V6.60645L5.47065 15.4707C5.21095 15.7304 4.78895 15.7304 4.52925 15.4707C4.26955 15.211 4.26955 14.789 4.52925 14.5293L13.3935 5.66504H6.66011C6.29284 5.66504 5.99507 5.36727 5.99507 5C5.99507 4.63273 6.29284 4.33496 6.66011 4.33496H14.9999L15.1337 4.34863C15.4369 4.41057 15.665 4.67857 15.665 5V13.3301C15.6649 13.6973 15.3672 13.9951 14.9999 13.9951C14.6327 13.9951 14.335 13.6973 14.3349 13.3301Z"></path></svg></span></a>.</p>
<h3 data-start="887" data-end="931">What happens during an EICR inspection</h3>
<p data-start="932" data-end="1354">Our qualified and experienced electricians will carry out a visual inspection of the installation to assess if there are any serious defects or items in need of repair before moving onto test individual circuits. Some testing will be carried out live whereas others will be carried out when the power is off. If your circuits are clearly and correctly labelled they can be switched off individually with less disruption.</p>
<h3 data-start="1356" data-end="1386">EICR cost and timeframes</h3>
<p data-start="1387" data-end="1713">The cost of an EICR inspection is determined by the number of distribution boards you have and the number of circuits to be tested. Where previous test records are provided, testing 20% of your installation should be sufficient but in the absence of test history, we will provide a quote to test the entire installation.</p>
<p data-start="1715" data-end="1950">For smaller properties such as flats, apartments and small commercial properties we usually allow half a day for testing whereas for larger properties or sites with a couple of buildings, we will advise customers to allow a few days.</p>
<p data-start="1952" data-end="2112">If you are a landlord or manage an HMO, you can find more details on our <a data-start="2025" data-end="2104" rel="noopener" target="_new" class="decorated-link" href="https://thefirepeople.co.uk/landlord-hmo-services/">Landlord and HMO Services<span aria-hidden="true" class="ms-0.5 inline-block align-middle leading-none"><svg width="20" height="20" viewbox="0 0 20 20" fill="currentColor" xmlns="http://www.w3.org/2000/svg" data-rtl-flip="" class="block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]"><path d="M14.3349 13.3301V6.60645L5.47065 15.4707C5.21095 15.7304 4.78895 15.7304 4.52925 15.4707C4.26955 15.211 4.26955 14.789 4.52925 14.5293L13.3935 5.66504H6.66011C6.29284 5.66504 5.99507 5.36727 5.99507 5C5.99507 4.63273 6.29284 4.33496 6.66011 4.33496H14.9999L15.1337 4.34863C15.4369 4.41057 15.665 4.67857 15.665 5V13.3301C15.6649 13.6973 15.3672 13.9951 14.9999 13.9951C14.6327 13.9951 14.335 13.6973 14.3349 13.3301Z"></path></svg></span></a> page.</p>
<h3 data-start="2114" data-end="2166">Understanding your EICR certificate and report</h3>
<p data-start="2167" data-end="2528">When our electrician has completed the test and inspection, we will provide a satisfactory or unsatisfactory report. The report will show details of the test and, if applicable, itemised issues with codes such as C1, C2. Where remedial works are required, we can provide a quotation to rectify these and then on completion, provide a satisfactory test report.</p>
<h3 data-start="2530" data-end="2573">Electrical safety and fire prevention</h3>
<p data-start="2574" data-end="2785">A significant amount of domestic fires are caused by old or faulty equipment which has not been maintained effectively. As with all compliance works, it is important to employ a competent and qualified person.</p>
<p data-start="2787" data-end="2904">For help arranging your inspection or to discuss compliance, <a data-start="2848" data-end="2901" rel="noopener" target="_new" class="decorated-link" href="https://thefirepeople.co.uk/contact-us/">contact us<span aria-hidden="true" class="ms-0.5 inline-block align-middle leading-none"><svg width="20" height="20" viewbox="0 0 20 20" fill="currentColor" xmlns="http://www.w3.org/2000/svg" data-rtl-flip="" class="block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]"><path d="M14.3349 13.3301V6.60645L5.47065 15.4707C5.21095 15.7304 4.78895 15.7304 4.52925 15.4707C4.26955 15.211 4.26955 14.789 4.52925 14.5293L13.3935 5.66504H6.66011C6.29284 5.66504 5.99507 5.36727 5.99507 5C5.99507 4.63273 6.29284 4.33496 6.66011 4.33496H14.9999L15.1337 4.34863C15.4369 4.41057 15.665 4.67857 15.665 5V13.3301C15.6649 13.6973 15.3672 13.9951 14.9999 13.9951C14.6327 13.9951 14.335 13.6973 14.3349 13.3301Z"></path></svg></span></a>.</p>
</div></div><div class="et_pb_module et_pb_button_module_wrapper et_pb_button_7_wrapper"><a class="et_pb_button_7 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module" href="https://thefirepeople.co.uk/contact-us/"><span class="et-pb-parallax-content">Get a quote</span></a></div>